Information About EIFS
Exterior Insulation and Finish Systems (EIFS),
sometimes referred to as synthetic stucco, typically consist
of five components: adhesive, insulation board (attached to
substrate with adhesive), a base coat into which a fiberglass
mesh is embedded, and a decorative finish coat in the desired
color. This type of system is called a face sealed barrier
EIFS and resists water penetration at its outer surface.
It is not intended to drain water that gets behind it. It
differs from other types of cladding that have a weather
resistive barrier behind the cladding (tar paper or house
wrap) and/or may have air spaces between the cladding and
substrate.

There are many types of cladding materials that
look like stucco. Traditional stucco is made of cement and is
different than EIFS cladding, which uses the five components
listed above. Other types of "hybrid" stucco include
polymer/cement base coat directly applied to a substrate, or
traditional stucco with an acrylic finish
coat.
How is water entering behind
EIFS?
Interfaces between EIFS and dissimilar
materials are a common source of water intrusion, not the EIFS
lamina (base coat and finish coat). The most frequent source
of water intrusion is windows. Water frequently enters the
EIFS at window locations in two ways: either through the joint
around the perimeter of the window or through seams and joints
in the window construction itself. Large quantities of water
resulting in some of the most severe damage have frequently
been discovered entering behind where a roof meets and
terminates at the lower edge of a wall. Other potential
sources of water intrusion are chimneys, decks and any other
penetration of the EIFS lamina.
Architectural design, severity of weather
(rainfall), exposure, and the performance and integration of
other building components usually determine whether water
infiltration behind the EIFS will occur. Although the
likelihood of penetration through the lamina is remote, water
can enter the system through cracks in the
lamina.
Why does water intrusion occur
behind EIFS, and why is it important to discover
it?
Water intrusion occurs through and/or around
building components such as windows, doors, gable vents,
penetrations, and a variety of flashing and construction
details. Water intrusion also occurs when maintenance is
ignored for these components and other critical areas, such as
caulk joints. It is important to discover the occurrence of
water intrusion, because water can enter behind the cladding
and wet unprotected sheathing, and in some cases, the wood
structural members. Depending upon climate and the overall
make-up of the wall assembly, the wall may not readily dry
out. As water intrusion continues to occur undetected in a
particular area, it can accrue to levels substantial enough to
cause damage. Early detection of water intrusion is the key to
minimizing and preventing such damage.
Is the location of water entry
visible, and is the damage
visible?
The location of water entry is often difficult
to see, and the damage to the substrate and structural members
behind the exterior wall cladding frequently cannot be
detected by a visual inspection.
Are the water intrusion problems
unique to any part of the
country?
No. While the problems were discovered in
Wilmington, North Carolina, this in no way means that you
could not have similar moisture intrusion problems where you
live. Field investigations of non-drainable EIFS in other
areas of the country have identified entrapped excessive
moisture resulting from water intrusion. The degree to which
the problem may exist in your area could be influenced by
local climatic conditions. The more rain, the greater the
likelihood of having water intrusion problems. In arid
climates, the opportunity for water intrusion is smaller, and
there is more opportunity for drying out of any incidental
water intrusion.
Should I have my EIFS home
periodically checked for elevated moisture
levels?
Yes. Testing should be done at least annually.
A combination of two moisture meters should be used: (1) a
non-invasive meter that scans through the wall without
penetrating the EIFS lamina, and (2) a probe-type meter that
penetrates the EIFS lamina and gives moisture readings of
materials in contact with the probes. Only a professional
experienced in EIFS water intrusion inspections should perform
these tests.
How serious are the problems if
water intrusion occurs in EIFS-clad
houses?
Damage can be significant if moisture intrusion
goes undetected. Damage can become more serious if allowed to
continue over time.
Any repair method undertaken should render the
house into a serviceable condition. The performance criterion
used to determine if a serviceable condition is being
sustained is a moisture assessment. A serviceable condition
exists when damage or excessive moisture is not detected
behind the EIFS cladding. This may be true even if the EIFS
manufacturer's standard specifications and construction
details were not originally followed. Localized removal of
EIFS may be necessary to facilitate repairs where damage is
discovered. Total removal of the cladding may not be
necessary.
Home owners who are deciding
whether to re-clad should consider the following questions:
·
Does the substrate have prolonged excessive
moisture that causes decay?
·
If water intrusion has occurred, what is the
extent of damage?
·
Do the areas requiring repair represent the
majority of the cladding area, or are they
localized?
·
Is the cost to repair the house in excess of the
cost to re-clad?
What are the repair
objectives?
The primary objective of repair is to eliminate
water intrusion. Repairs should be made where elevated
moisture is detected or structural integrity of the material
is impaired. Where structural damage has occurred, those areas
require replacement of decayed wood products in addition to
eliminating the source of water intrusion. Areas of elevated
moisture in the absence of damage or decay may require no more
than eliminating the source of water intrusion. It has been
discovered that wet but undamaged substrate can dry out over
time once the source of the water intrusion has been
eliminated. Repair methods should address leaks associated
with but not limited to:
Roofs
- Install effective kick-out flashing at roof-to-wall
intersections, diverter flashing around trapped valleys, and
rake flashing.
Caulk
Joints - Install effective caulk
joints.
Windows
and Doors - Caulk window jamb to sill joint and joints
in any molding surrounding the window or door. Specially
designed sill flashing is needed below most types of windows
and most windows that are mulled
together.
Decks
- Install effective
flashing.
Chimneys
- Install effective cap flashing, cricket flashing at
trapped valley, and effective kick-out flashing for roof-rake
wall intersections.
Other
Penetrations - Install effective caulk joint and/or
flashing.
Cracks
and Damaged EIFS Lamina - Repair according to
manufacturer's specifications.
Effective implies that flashing and caulking
prevents water intrusion. Special care, craftsperson skill and
design consideration are required to make repairs and install
flashing.
Repairs for every component, penetration,
architectural detail and flashing detail have not been
submitted to or reviewed by the EIFS Review Committee. Some
repair methods have been developed in laboratory conditions
and are currently being tested and monitored in the field for
effectiveness. Preliminary test data indicate that effective
repairs to some limited components frequently used in EIFS can
be achieved. The repairs do not restore windows, flashing or
EIFS to match the EIFS manufacturer's original specifications
or details, but focus on eliminating leaks by modifying the
as-built conditions. The effectiveness of any repair is
dependent upon accurate diagnosis of the source of water
intrusion and the skill of the contractor making the repair.
The repair is performing successfully when elevated moisture
diminishes to an acceptable level over time and does not recur
in sustained elevated levels in the long
term.
Should the repair be
monitored?
Yes. You should hire a professional experienced
in EIFS water intrusion inspection to perform follow-up
inspections within six months after the repair. Then once
every year, the effectiveness of the repair should be
monitored as part of the whole house moisture survey. If the
repair is not successful, elevated moisture levels will be
detected, and the repair method should be evaluated for the
reason for failure. After making additional repairs, follow up
with another inspection until such time that the moisture
level becomes acceptable.
How should the home be
maintained?
Frequent visual inspections should include
thorough checking of windows, flashing and sealant/caulk.
Damaged flashing should be repaired or replaced immediately.
Cracks or deteriorated sealants should be repaired or removed
and replaced. Periodic moisture testing would be prudent,
especially for houses that were diagnosed with elevated
moisture levels. Homeowners should refer to the manufacturer's
maintenance and repair instructions. Information is also
available from the National Association of Home Builders
(NAHB) Research Center's HomeBase Hotline at 800-898-2842, and
the Research Center's Website at
www.nahbrc.org.
If you have additional technical questions
about EIFS, please contact the Home Base Hotline at the NAHB
Research Center. The toll-free number is 1-800-898-2842.